Search in the site

Advanced Search

IPM 112B V400

Brushless synchronous motors

Energy efficiency, reliability and high performance in a single product.

The PM IE4 motor makes it possible to obtain a return on the initial investment after few months from its start-up, as electricity consumption decreases compared to an IE1 motor.
In addition to having these real economic savings, the use of IE4 motors increases the reliability and performance of the entire system.

TECHNICAL FEATURES

  IPM 112B 5,5-11,0kW 400V IE4
THREE-PHASE 400V INVERTER POWER SUPPLY
MOTOR IC411 (self-ventilated) 5,5 kW 11,0 kW
Description Symbol Units of measure Nominal Speed
1500 RPM 3000 RPM
Frequency f [Hz] 100 200
Number of Poles 2p   8 8
Maximum No-load speed n_max [RPM] 2800 5000
Constant voltage Ke [V_rms/KRPM] 170,0 85,0
Constant torque Kt [Nm/A_rms] 2,67 1,33
Rated torque Cnom [Nm] 35,0 35,0
Rated current Inom [A_rms] 13,1 26,2
Efficiency η [%] 91,9 92,6
Maximum torque Cmax [Nm] 42,7 38,5
Maximum torque current Imax [A_rms] 16,3 28,8
Minimum switching requency f_switch [kHz] 4 4
Phase resistance @T_amb Rs [Ω] 1,6 0,39
Direct axis inductance Ld [mH] 5,1 1,3
Quadrature axis inductance Lq [mH] 11,4 2,1
Magnetic flux ϕe [mWb] 0,315 1,33
Motor weight P [kg] 24,6
Room temperature T_amb [°C] -15 ÷ 40
 IP degree of protection IP   55
Insulation class     F
Overtemperature Dt [°C] 45 56
Type of service     S1

 

 

Operating torque curve 5,5kW - 1500 RPM

 

Operating power curve 5,5kW - 1500 RPM

 

 

Operating torque curve 11,0kW - 3000 RPM

 

Operating power curve 11,0kW - 3000 RPM